The proper use of equipment, maintenance and serious implementation of the security operation is to extend the useful life of equipment to ensure that the necessary conditions for safe production. Therefore, the operator should be familiar with the first performance of the structure of the machinery and equipment and operating procedures. According to the general use of maintenance for the user to make a few reference.
1) N46 work to recommend the use of oil, hydraulic oil wear (GB443-84), hydraulic oil should be selected as the temperature. At room temperature lower than 20 ℃, the N32 can be used, wear hydraulic oil, at room temperature higher than 30 ℃, can be used, wear N46 or N68 hydraulic oil, hydraulic oil wear. The use of oil temperature should be 15 ℃ - 55 ℃. As the room temperature, the specific circumstances the use of visual cooler, the general temperature in the fuel tank should be open for more than 45 ℃ cooler for cooling.
2) 24μ oil should be used strictly for the oil filter before adding the filter tank. Fuel tank with fuel oil should not be lower than the standard requirements.
3) Oil filter should be cleaned frequently with kerosene, the work of oil every 2,000 hours of work a replacement.
4)Pressure gauge should check every six months and a correction.
5) Machinery out for a long time, the surface should be cleaned painted with anti-rust oil.
6) Lubrication:
a: On the blade shearing blades and under the seat between the punch and die carrier punch shot between the injection hole, the sliding frame and printers between the Rail, as well as other moving parts should be injected into the regular N46, lubricants, each time starting Oiling before re-starting.
b: Screw before the start oiling first class.
c: Transmission surface mesh rack, the chain of transmission to the regular Tu ZG-2H-based synthesis of calcium grease (SY1409-76) for lubrication.
d: Taiwan is expected horizontal, flip Rack, etc. reducer for the first time before the start should be injected into the N46, hydraulic oil every six months should be replaced with a reducer of lubricants.
e: Drive rack rail surface coating should be N46, hydraulic oil and a mixture of calcium-based grease for lubrication, every work week, an oil painted. |